Order before 16:00 on business days? Shipped the same day!

Fast & reliable shipping throughout Europe

Expert customer service with professional advice

Mega Sale: Discounts up to 75%! While supplies last!

Jaltest  |  SKU: 78500001

Jaltest (78500001) | Iveco SGW (Company) | Update License

Regular price
€106,95 incl.
€88,39 excl.

License Duration

Warranty directly via AsTools

We handle warranty cases ourselves, quickly and without involving the manufacturer. Thanks to our own parts inventory and technical expertise, we can usually assist you immediately. Only in exceptional cases do we still send the product to the supplier.

2 years warranty on all products

All our products come with a 2-year factory warranty. This ensures you long-lasting quality and service.

Easy returns

You can easily request your return through your account. We will send you the return label by email. Return shipping costs are your responsibility.

Professional customer service

Our experts are ready to help you quickly and professionally, both online and in our physical store. Questions? Feel free to contact us!

The Jaltest 78500001 is the SGW corporate renewal licence for Iveco: this extends the corporate portion of an active Security Gateway authorisation. Renewal must be done simultaneously per device (78500002), and only within the window of 1 November to 15 December.

Without authorisation, you can read data on these vehicles, but cannot control components, perform calibrations or reset maintenance functions. Jaltest is approved by the manufacturer as a diagnostic tool and manages the connection to the authentication server; this licence opens that connection for you. The renewal is valid for the following calendar year, until 31 December. You purchase this portion once per workshop, no matter how many Jaltest Links you operate: it is tied to your business registration, not to individual units.

KEY BENEFITS

Full diagnostics on vehicles with Security Gateway: control functions, calibrations and maintenance features become available.
Jaltest is approved by Iveco as a compatible tool; you work through the official authentication server.
One company registration per workshop, regardless of how many Jaltest Link units you own.
If you expand later with an additional Jaltest Link, you only add the device-level part; you already have this part.

POINTS TO NOTE

Renewal is only possible from 1 November to 15 December. If you miss this deadline, you must purchase the full activation again (70607002 and 70607003).
The renewal is valid for the following calendar year and runs until 31 December of that year.
Activation is not immediate: the manufacturer must first approve your request.
When ordering, provide the serial number of your Jaltest Link and your company details; these are sent to the manufacturer for approval.

What is the Security Gateway?

Newer Iveco vehicles feature a Security Gateway (SGW): a security module between the diagnostic port and control units that prevents unauthorised access. To pass through it, you must identify yourself to the manufacturer. Jaltest does this for you once this authorisation is loaded on your device.

What is blocked without authorisation

  • Control functions: activate components to test them
  • Calibrations: retrain sensors and systems
  • Maintenance functions: service resets and maintenance procedures

Data reading remains available: reading fault codes and monitoring live data works even without authorisation.

What you can do after activation

With authorisation on your Jaltest, you can perform everything you do on other vehicles with these models: bidirectional tests, calibrations, maintenance and all other steps of a complete repair.


Which vehicles are covered

This authorisation applies to Iveco models that Jaltest supports with Security Gateway. Available functions per model depend on Jaltest coverage.

  • Daily: Daily from 2019 onwards, Daily CNG and Minibus Daily from 2019
  • Heavy range: S-Way, S-Way NP, T-Way, X-Way and X-Way NP
  • Buses: Crossway and Crossway LE

For other makes, there is a separate authorisation: FCA SGW (70607001).


What you need

The authorisation works on top of your Jaltest diagnostic licence. The full breakdown is shown below.

  • Jaltest Link V8 or newer: older Links cannot establish the secure connection.
  • An active Jaltest diagnostic licence: for the vehicle you want to diagnose, such as Jaltest CV, Modular or Truck Select with this brand included.
  • An active SGW authorisation: this renewal works only on an activation from this year.
  • SGW renewal per business (78500001): this product. Once per workshop.
  • SGW renewal per device (78500002): once per Jaltest Link.

Workshop and device

Iveco registers the workshop and each device separately. That's why the authorisation consists of two products: one per company and one per Jaltest Link. You add extra devices later using only the device portion.

Your situation Per workshop (78500001) Per device (78500002)
One Jaltest Link 1x 1x
Two Jaltest Links 1x 2x
Three Jaltest Links 1x 3x

Duration and renewal

Iveco works with calendar years. An activation is valid until 31 December of the year in which you purchase it, even if that is late in the year.

  • Renewal: from 1 November to 15 December, using the renewal per company (78500001) and per device (78500002). Access then continues into the new year.
  • Missed deadline: if you apply after 15 December, the renewal expires and you must purchase the full activation again, per company (70607002) and per device (70607003).
  • Pricing policy: Cojali may adjust SGW rates after written notice; requests always go through Cojali.
💡
Worth knowing: if you purchase the activation late in the year, it will have a short term. Set a reminder for November to renew, otherwise you'll need a full activation again in January.

What's included

  • 1x Iveco SGW renewal per business
  • Term: the following calendar year, until 31 December
  • Authorisation linked to your serial number: tied to the Jaltest Link whose serial number you provide
  • No physical shipment: Nothing is packaged or sent

How the activation process works

Unlike a standard licence, the manufacturer is involved here. From order to working authorisation, there are four steps.

  1. Place your order: include the serial number of your Jaltest Link and your company details in the notes field.
  2. We submit the request: we send your details through Cojali to Iveco.
  3. Approval by the manufacturer: Iveco reviews the request. This takes longer than a standard licence; do not expect the same day.
  4. Access: Once approval is received, the authorisation will be activated on your Jaltest and you will be notified by email.

Technical specifications

Specification Description
Brand Jaltest (Cojali)
Reference number 78500001
Type SGW renewal Iveco, per workshop
Duration The following calendar year, until 31 December
Per Workshop
Part of Renewal per device (78500002)
Renewal From 1 November to 15 December
Vehicle manufacturer Iveco
What is included Control modules, calibrations and maintenance functions
Required to use Jaltest Link V8 or newer and an active Jaltest diagnostic licence
Activation After manufacturer approval; not immediate
Serial number Mandatory at order, with workshop details
Delivery Digital – no physical shipment