Order before 15:00 on business days? Shipped the same day!

Fast & reliable shipping throughout Europe

Expert customer service with professional advice

Mega Sale: Discounts up to 75%! While supplies last!

VikTec  |  SKU: 4B - VT14104

VT14104 | Forming Gas Leak Detector

Regular price
€114,95 incl.
€95,00 excl.

Warranty directly via AsTools

We handle warranty cases ourselves, quickly and without involving the manufacturer. Thanks to our own parts inventory and technical expertise, we can usually assist you immediately. Only in exceptional cases do we still send the product to the supplier.

2 years warranty on all products

All our products come with a 2-year factory warranty. This ensures you long-lasting quality and service.

Easy returns

You can easily request your return through your account. We will send you the return label by email. Return shipping costs are your responsibility.

Professional customer service

Our experts are ready to help you quickly and professionally, both online and in our physical store. Questions? Feel free to contact us!

The VT14104 is a forming gas tester for detecting leaks in air conditioning systems and other closed pipe systems. The system is filled with forming gas: 95% nitrogen and 5% hydrogen. The tester responds to the hydrogen that escapes from a leak, with a sensitivity below 5 ppm.

A semiconductor sensor is located at the end of a flexible stainless steel probe of 40 cm, so you can also reach evaporators, condensers and pipes behind panels. A leak is indicated by a three-colour LED and an audible signal. The sensitivity is adjustable and the tester automatically resets to zero in the ambient air.

PLUSPUNTEN

✔Highly sensitive — Responds to hydrogen below 5 ppm.
✔Flexible probe — 40 cm stainless steel, for hard-to-reach areas.
✔LED and sound — See and hear a leak, even without looking at the device.
✔Supplied complete — With batteries and storage case.

AANDACHTSPUNTEN

✕Forming gas only — Detects hydrogen, not refrigerants such as R134a or R1234yf.
✕Forming gas not included — Purchase the cylinder and filling set separately.
✕Recover refrigerant first — Only then fill the system with forming gas.
✕Draughts affect the measurement — Wind disperses the hydrogen at the leak.

Applications and functionality

The VT14104 is intended for air conditioning specialists and workshops who want to locate leaks that are difficult to find with UV tracer dye or a refrigerant leak detector.

Operation

  • Forming gas: 95% nitrogen and 5% hydrogen, non-flammable.
  • Hydrogen as tracer gas: The small molecule also escapes through very small leaks.
  • Semiconductor sensor: Responds to hydrogen below 5 ppm.
  • Automatic zeroing: The ambient air is used as the zero point.

What you use it for

  • Air conditioning system: Leaks in evaporators, condensers, pipes and couplings.
  • After repair: Check that connections are sealed before filling.
  • Difficult leaks: Where UV tracer dye does not give a clear result.

How to use it

  1. Emptying the system: Have the refrigerant recovered.
  2. Filling with forming gas: Pressurise the system with forming gas.
  3. Switching on the tester: Switch it on in clean air so that it reads zero.
  4. Selecting sensitivity: Start coarse and increase the sensitivity to locate the leak.
  5. Searching: Move the probe slowly along pipes and couplings; the LED and sound indicate the leak.

Special functions and features

What makes the VT14104 practical:

  • Adjustable sensitivity: From large leaks to very small ones.
  • Three-colour LED: Indicates the concentration.
  • Audible signal: Warns when gas is detected.
  • Storage case: Tester and probe stored protected.

Package contents

  • 1x VT14104 with flexible probe (40 cm)
  • 4x AA batteries
  • 1x Storage case
  • 1x User manual
💡
Good to know: Hydrogen is lighter than air and rises. Therefore, search mainly above and beside the pipes and couplings, and work from top to bottom.

Technical specifications

General

The manufacturer of the tester.Brand
VikTec
The type of device, so that you know what it is used for.Device type
Forming gas tester
The gas the tester detects. With forming gas, this is the hydrogen that escapes through a leak.Gas detected
Hydrogen (H2)

Measurement

Whether you can choose how sensitive the tester is. Useful for searching roughly first and then precisely.Adjustable sensitivity
Yes
The type of sensor that measures the gas. This partly determines how sensitive and fast the tester is.Sensor type
Semiconductor
The tester calibrates itself to the ambient air, so that you can measure reliably straight away.Automatic zeroing
Yes
The length of the measuring probe. A longer probe makes it easier to reach awkward spots.Probe length
40 cm
Whether the probe can be bent to search behind components and in tight spaces.Flexible probe
Yes

Signalling

Whether the tester uses lights to show how much gas it detects.LED indicator
Yes
Whether the tester beeps when it detects a leak, so that you do not need to keep looking at the device.Audible signal
Yes

Included

Whether a case is included for storing the tester and probe safely.Storage case
Yes

Other specifications

Detected gas
Hydrogen in forming gas (95% N2, 5% H2)
Sensitivity
Below 5 ppm, adjustable
Signalling
Tri-colour LED and audible alarm
Zeroing
Automatic
Power supply
4 × AA (included)