Order before 15:00 on business days? Shipped the same day!

Fast & reliable shipping throughout Europe

Expert customer service with professional advice

Mega Sale: Discounts up to 75%! While supplies last!

Jaltest  |  SKU: JDC516A

Jaltest (JDC516A) | Landini 4-pins OBD – 16-pins OBD2 Adapter Cable | Agricultural Vehicle

Regular price
€114,95 incl.
€95,00 excl.

Warranty directly via AsTools

We handle warranty cases ourselves, quickly and without involving the manufacturer. Thanks to our own parts inventory and technical expertise, we can usually assist you immediately. Only in exceptional cases do we still send the product to the supplier.

2 years warranty on all products

All our products come with a 2-year factory warranty. This ensures you long-lasting quality and service.

Easy returns

You can easily request your return through your account. We will send you the return label by email. Return shipping costs are your responsibility.

Professional customer service

Our experts are ready to help you quickly and professionally, both online and in our physical store. Questions? Feel free to contact us!

The Jaltest JDC516A connects the proprietary 4-pin diagnostic connector of a Landini tractor to the 16-pin OBD2 port of your Jaltest equipment. On the machine side is a fully black 4-pin plug with a rounded, oval shape, a locking tab in the centre of the top side, and a straight cable entry in an overmoulded strain relief. A coloured contact holder is absent. The cable is 28 to 30 cm long.

When connected with the cable, the Jaltest software accesses the ECM 1100C (Tier 2 / Stage II), the electronic diesel control present on all covered series. On the Powerfarm series, the transmission control TRANS (Sauer Danfoss) and the instrument panel are also accessible. The cable works with the Jaltest Link V8.1 and V9 and falls under Jaltest AGV.

ADVANTAGES

✔Direct access to the ECM 1100C (Tier 2 / Stage II), the electronic diesel control that Landini used across the entire Tier 2 generation.
✔On the Powerfarm series, you also reach the transmission control TRANS (Sauer Danfoss) and the instrument panel.
✔One plug for a wide range of series: Legend, Rex, Powerfarm, Landpower, Alpine, Mythos, Powermondial and Powerful.
✔Works with both interface generations, the Jaltest Link V8.1 and the V9.

POINTS TO NOTE

✕On the Legend series, Jaltest covers the engine control only; transmission and instrument panel fall outside the coverage.
✕On these Landini systems, the service intervals, diagnostic warnings and additional actions are not available; it is limited to fault codes, measured values and ECU data.
✕Only for the 4-pin Landini connector; other tractor brands use their own plug.
✕The year of manufacture is not conclusive, as Landini kept this plug over a long range of years.

Applications and functionality

The cable is intended for workshops and contractors who read Landini tractors with the Jaltest Link. The control units present differ by series. The engine control is found on all of them; the transmission and instrument panel only on the Powerfarm.

Control units you can access

  • ECM 1100C: Diesel control, Tier 2 / Stage II.
  • TRANS (Sauer Danfoss): Transmission, Powerfarm.
  • Cluster: Instrument panel, Powerfarm.

What you can do

  • Fault codes: Read and clear, with descriptions.
  • Measured values: View current sensor values.
  • Alarm limits: Set for deviating values.
  • ECU data: Data from the control unit.

How to use it

  1. Locate the plug: Find the black 4-pin connector in the cab.
  2. Connect: Insert the JDC516A into the connector.
  3. Link connection: Connect the OBD2 end to the Jaltest Link.
  4. Ignition on: Switch the ignition on.
  5. Read out: Select Landini and the series in the Jaltest software.

Compatible vehicles and applications

The plug determines compatibility, not the model. The cable fits any Landini tractor with the proprietary 4-pin diagnostic connector. Below are the series within Jaltest AGV coverage; the years of manufacture indicate the period in which Jaltest supports those series, not the presence of this plug.

Landini:

  • Legend series: 1993 - 2005, Tier 2 / Stage II.
  • Rex series: 2001 - 2020, Tier 2 / Stage II.
  • Powerfarm series: 2004 - 2020, Tier 2 / Stage II.
  • Landpower series: 2005 - 2023, Tier 2 / Stage II.
  • Alpine series: 2005 - 2008, Tier 2 / Stage II to Tier 3 / Stage III.
  • Mythos series: Tier 2 / Stage II.
  • Powermondial series: Tier 2 / Stage II.
  • Powerful series: Tier 2 / Stage II to Tier 3 / Stage III.
💡
Good to know: The 4-pin Landini plug is located in the cab, is fully black and has a locking tab in the centre of the top side; a coloured contact holder is absent. This sets it apart from the red and yellow versions on other tractor brands. Check on the tractor itself which connector is fitted before ordering.

Package contents

  • 1x Jaltest (JDC516A) | Landini 4-pin OBD – 16-pin OBD2 Adapter Cable | Agricultural Vehicle

Technical specifications

General

The manufacturer of the cable. Jaltest cables work with Jaltest diagnostic equipment.Brand
Jaltest (Cojali)
The type of cable. A diagnostic cable connects to the diagnostic socket, a measuring cable tests an individual component.Cable type
Adapter cable
The Jaltest software package the cable belongs to. A licence for that module is required to use the cable.Jaltest software module
  • AGV agriculture
The types of vehicles or machines the cable is intended for. This shows quickly whether it suits the vehicles entering your workshop.Vehicle types
  • Agricultural vehicle

Connections

The version of the Jaltest Link diagnostic interface the cable fits. Not every cable works with every version.Compatible Jaltest Link
  • Jaltest Link V8.1
  • Jaltest Link V9
The connector on the diagnostic device side. It must fit your interface or diagnostic cable.Interface-side connector
16-pin OBD2
The connector on the vehicle, engine or machine side. It must fit the diagnostic socket or the component.Vehicle-side connector
4-pin OBD
The length of the cable. A longer cable allows more room to work.Cable length
28 to 30 cm

Diagnostics

Whether fault codes can be cleared as well as read. Some systems only allow reading.Clear fault codes
Yes
Whether the current sensor values can be viewed while the vehicle is running. Useful for tracing a fault.View live data
Yes

Usage

The Jaltest cable set that also contains this cable. If you already own that set, you may already have this cable.Part of cable set
AGV cable set
Reference number
JDC516A

Other specifications

Application
Landini tractors with the 4-pin diagnostic connector
Control units
ECM 1100C (engine), TRANS Sauer Danfoss (transmission), Cluster (instrument panel)
Part of cable set
AGV cable set (70002003)
Required for use
Jaltest Link V8.1 or V9 with a licence for Jaltest AGV