{"product_id":"jaltest-jt2001-multimeter","title":"Jaltest JT2001 | Multimeter","description":"\u003cdiv style=\"font-family:sans-serif; line-height:1.6; color:#374151; font-size:15px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eJaltest JT2001\u003c\/strong\u003e is a \u003cstrong\u003edigital multimeter\u003c\/strong\u003e for performing a wide range of electrical measurements. The instrument measures \u003cstrong\u003eDC voltage (DCV)\u003c\/strong\u003e, \u003cstrong\u003eAC voltage (ACV)\u003c\/strong\u003e, \u003cstrong\u003eDC current (DCA)\u003c\/strong\u003e and \u003cstrong\u003eresistance (Ω)\u003c\/strong\u003e. The meter features an easy-to-read \u003cstrong\u003e3½-digit LCD display\u003c\/strong\u003e with a maximum reading of 1999 counts. For added safety, the device is equipped with a \u003cstrong\u003enon-contact voltage detector (NCV)\u003c\/strong\u003e and complies with the safety standard \u003cstrong\u003eCAT II 250V\u003c\/strong\u003e according to EN 61010-1 and EN 61010-2-030.\u003c\/p\u003e\n\u003cp\u003eBeyond basic measurements, the JT2001 offers additional functions such as a \u003cstrong\u003ediode test\u003c\/strong\u003e and a \u003cstrong\u003econtinuity test\u003c\/strong\u003e with audible buzzer. The \u003cstrong\u003edata hold function\u003c\/strong\u003e lets you freeze a reading on the display for later reference. For use in poorly lit environments, the display features a backlight. The multimeter automatically powers off after ten minutes of inactivity to conserve battery life, and includes a low battery indicator.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:20px; margin:30px 0; align-items:stretch;\"\u003e\n\u003cdiv style=\"flex:1; min-width:250px; background:#ffffff; border:1px solid #e5e7eb; border-radius:8px; padding:20px;\"\u003e\n\u003ch3 style=\"color:#166534; text-transform:uppercase; font-size:13px; font-weight:800; border-bottom:2px solid #22c55e; padding-bottom:10px; margin-top:0;\"\u003eKEY FEATURES\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eNon-contact voltage detection (NCV)\u003c\/strong\u003e — Detects the presence of AC voltage without touching or piercing the wiring.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eData hold with backlight\u003c\/strong\u003e — Freezes the reading on the illuminated display, so you can measure in hard-to-reach places and read the result later.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eFused 10A input\u003c\/strong\u003e — A separate fused connection enables current measurements up to 10A without straining the instrument.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eAuto power-off\u003c\/strong\u003e — Automatically shuts down after ten minutes of inactivity, with an indicator that warns you in time of low battery voltage.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; background:#ffffff; border:1px solid #e5e7eb; border-radius:8px; padding:20px;\"\u003e\n\u003ch3 style=\"color:#991b1b; text-transform:uppercase; font-size:13px; font-weight:800; border-bottom:2px solid #ef4444; padding-bottom:10px; margin-top:0;\"\u003eCONSIDERATIONS\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eManual range selection\u003c\/strong\u003e — The measurement range must be selected in advance using the rotary dial; the instrument does not auto-range.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eDC current measurement only\u003c\/strong\u003e — The meter measures DC current up to 10A; AC current measurement is not available.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eBatteries not included\u003c\/strong\u003e — The device operates on two 1.5V AAA batteries, which are not included in the package contents.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eNever measure above 250Vrms\u003c\/strong\u003e — The instrument is designed for a CAT II 250V environment; higher voltages pose a risk of electric shock.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eApplication and functionality\u003c\/h2\u003e\n\u003cp\u003eThe JT2001 is a compact tool for diagnosing and testing electrical circuits and components across various applications, including the automotive sector.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage measurement, AC and DC:\u003c\/strong\u003e For checking battery voltage, alternator output, sensors, and power supply circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent measurement, DC:\u003c\/strong\u003e Measures current in DC circuits via a separate fused input for measurements up to 10A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance measurement:\u003c\/strong\u003e Ideal for continuity checks on wiring, testing sensors, and verifying component resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity test:\u003c\/strong\u003e A quick check for breaks in cables or circuits, with a clear beeper for confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiode test:\u003c\/strong\u003e For verifying proper operation of diodes and other semiconductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-contact voltage detection (NCV):\u003c\/strong\u003e Allows you to detect the presence of AC voltage in cables or outlets without physical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData hold:\u003c\/strong\u003e Freezes the current reading on the display, convenient for measurements in hard-to-reach locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay backlight:\u003c\/strong\u003e A manually activated backlight improves readability in dark working conditions and automatically turns off after 30 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eMeasurement ranges\u003c\/h2\u003e\n\u003cp\u003eThe multimeter features manually selectable measurement ranges for accurate testing of various electrical quantities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC voltage (DCV):\u003c\/strong\u003e 200mV \/ 2V \/ 20V \/ 200V \/ 260V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC voltage (ACV):\u003c\/strong\u003e 2V \/ 20V \/ 200V \/ 250V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC current (DCA):\u003c\/strong\u003e 2000µA \/ 20mA \/ 200mA \/ 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance (Ω):\u003c\/strong\u003e 200Ω \/ 2kΩ \/ 20kΩ \/ 200kΩ \/ 2MΩ \/ 20MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuity:\u003c\/strong\u003e Audible signal at a resistance below approximately 50 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiode test:\u003c\/strong\u003e Displays the forward voltage drop of a diode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003ePackage contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Jaltest JT2001 digital multimeter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Test lead set, red and black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Protective rubber carrying case\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e User manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#fff7ed; border-left:4px solid #f97316; padding:15px; margin:25px 0; font-size:14px; color:#9a3412; border-radius:0 6px 6px 0; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"font-size:20px; margin-right:12px;\"\u003e💡\u003c\/span\u003e\u003cdiv\u003e\n\u003cstrong\u003eGood to know:\u003c\/strong\u003e When measuring current, move the red test lead to the separate 10A input and set the rotary dial to the corresponding position. If the lead remains in the voltage input while measuring current, it will create a short circuit across the measurement circuit and blow the fuse. Always switch the meter back to voltage mode after taking current measurements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; margin:20px 0; border:1px solid #d1d5db;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#f9fafb;\"\u003e\n\u003cth style=\"text-align:left; padding:12px 16px; border:1px solid #d1d5db; color:#111827; font-weight:700; width:50%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left; padding:12px 16px; border:1px solid #d1d5db; color:#111827; font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eProduct brand\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eJaltest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eProduct model\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eJT2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eDigital multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eSafety category\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eCAT II 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eLCD, 3½ digit, 1999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMeasurement method\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eManual range selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eDC voltage (DCV)\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e200mV to 260V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eAC voltage (ACV)\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e2V to 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eDC current (DCA)\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e2000µA to 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e200Ω to 20MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eFrequency range (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e40Hz - 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eApproximately 10MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eAdditional Features\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eDiode test, continuity test, data hold, NCV and backlit display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eAuto Power-Off\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eYes, after 10 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eLow Battery Indicator\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e2 to 3 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eFuses\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eF1: 200mA\/250V, 5 x 20 mm · F2: 10A\/250V, 5 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e2x 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e0°C to 40°C at less than 80% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e-10°C to 50°C at less than 85% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eEN 61010-1, EN 61010-2-030 and EN 61326, pollution degree II, double insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eApproximately 206 g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eItem Number\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e50002001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Jaltest","offers":[{"title":"Predeterminado","offer_id":51271556170035,"sku":"50002001","price":24.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0912\/5874\/9235\/files\/Jaltest-JT2001-Multimeter.webp?v=1780306713","url":"https:\/\/www.astools.eu\/es\/products\/jaltest-jt2001-multimeter","provider":"AsTools","version":"1.0","type":"link"}