{"product_id":"autool-lm120-aircomanometer","title":"Autool LM120 | AC Manifold Gauge","description":"\u003cdiv style=\"font-family: sans-serif; line-height: 1.6; color: #374151; font-size: 15px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eAutool LM120\u003c\/strong\u003e is a \u003cstrong\u003edigital air conditioning manifold gauge\u003c\/strong\u003e for installing, maintaining and inspecting refrigeration systems and air conditioning units. The gauge measures pressure in a range of \u003cstrong\u003e0 to 6000 kPa\u003c\/strong\u003e and vacuum from \u003cstrong\u003e-101 to 0 kPa\u003c\/strong\u003e. The temperature range spans \u003cstrong\u003e-40 °C to 150 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe device is equipped with a built-in database of \u003cstrong\u003e89 refrigerants\u003c\/strong\u003e with corresponding pressure and saturation temperature data. It features dual pressure and temperature measurement, vacuum measurement, pressure loss testing and a \u003cstrong\u003esight glass\u003c\/strong\u003e for visual inspection of refrigerant status. All measurements are clearly displayed on the backlit LCD screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin: 30px 0; align-items: stretch;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; background: #ffffff; border: 1px solid #e5e7eb; border-radius: 8px; padding: 20px;\"\u003e\n\u003ch3 style=\"color: #166534; text-transform: uppercase; font-size: 13px; font-weight: 800; border-bottom: 2px solid #22c55e; padding-bottom: 10px; margin-top: 0;\"\u003eKEY FEATURES\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #16a34a; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003e89 refrigerants in database\u003c\/strong\u003e — automatic calculation of saturation and condensation temperatures.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #16a34a; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003eDual pressure \u0026 temperature\u003c\/strong\u003e — simultaneous HP\/LP and saturation\/condensation readings on one screen.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #16a34a; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003ePressure loss test \u0026 vacuum\u003c\/strong\u003e — check for leaks and detect moisture or non-condensable gases.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; background: #ffffff; border: 1px solid #e5e7eb; border-radius: 8px; padding: 20px;\"\u003e\n\u003ch3 style=\"color: #991b1b; text-transform: uppercase; font-size: 13px; font-weight: 800; border-bottom: 2px solid #ef4444; padding-bottom: 10px; margin-top: 0;\"\u003eIMPORTANT NOTES\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #dc2626; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003eBatteries not included\u003c\/strong\u003e — 4x AA batteries to be purchased separately.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #dc2626; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003eProfessional use only\u003c\/strong\u003e — F-gas work in the Netherlands requires certification for air conditioning system servicing.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n\u003cspan style=\"color: #dc2626; font-weight: 900; margin-right: 10px; font-size: 16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size: 14px; color: #4b5563; line-height: 1.6;\"\u003e\u003cstrong\u003eBase model\u003c\/strong\u003e — for extended features see the LM120+.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e5e7eb; margin: 40px 0;\"\u003e\n\u003ch2 style=\"border-left: 5px solid #006aff; padding-left: 15px; font-weight: 800;\"\u003eApplication and functionality\u003c\/h2\u003e\n\u003cp\u003eThe LM120 offers various measurement modes for comprehensive air conditioning system analysis:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure and temperature test:\u003c\/strong\u003e Simultaneously measure pressure and temperature on both the high-side and low-side of the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporation pressure and temperature (Ev):\u003c\/strong\u003e Calculates and displays the transition from liquid to gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensation pressure and temperature (Co):\u003c\/strong\u003e Calculates and displays the transition from gas to liquid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure drop test:\u003c\/strong\u003e Leak test via pressure differential (ΔP) over a set period.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant selection:\u003c\/strong\u003e Choose from a database of 89 types for accurate calculations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum measurement:\u003c\/strong\u003e Check for the absence of non-condensable gases and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #fff7ed; border-left: 4px solid #f97316; padding: 15px; margin: 25px 0; font-size: 14px; color: #9a3412; border-radius: 0 6px 6px 0; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"font-size: 20px; margin-right: 12px;\"\u003e⚠️\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e In the Netherlands, work on systems containing F-gases (including most automotive refrigerants such as R134a and R1234yf) requires \u003cstrong\u003eSTEK certification\u003c\/strong\u003e for the technician.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e5e7eb; margin: 40px 0;\"\u003e\n\u003ch2 style=\"border-left: 5px solid #006aff; padding-left: 15px; font-weight: 800;\"\u003ePackage contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Autool LM120 digital air conditioning manifold gauge\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e User manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e5e7eb; margin: 40px 0;\"\u003e\n\u003ch2 style=\"border-left: 5px solid #006aff; padding-left: 15px; font-weight: 800;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cstyle\u003etable.specs-table{width:100%;border-collapse:collapse}table.specs-table th,table.specs-table td{border:1px solid #ccc;padding:10px;vertical-align:top;text-align:left}table.specs-table th{background-color:#f8f8f8;font-weight:bold;width:25%;white-space:nowrap}\u003c\/style\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLM120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure test range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 6000 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% FS + 5 dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum pressure load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 kPa (10 MPa \/ 100 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVacuum test range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-101 – 0 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Test Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 150 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C + 2 dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ekPa, MPa, Bar, inHg, PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C, °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Database\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89 types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x 1.5V AA (LR6) batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 x 110 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e950 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Autool","offers":[{"title":"Default","offer_id":51271508623667,"sku":"LM120","price":107.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0912\/5874\/9235\/files\/Autool-LM120-Aircomanometer_8052ae5b.webp?v=1780308581","url":"https:\/\/www.astools.eu\/es\/products\/autool-lm120-ac-manifold-gauge","provider":"AsTools","version":"1.0","type":"link"}