{"title":"Wood moisture meter","description":"\u003cp data-start=\"29\" data-end=\"299\" style=\"text-align: center;\"\u003eWith a professional paint thickness gauge from AsTools, you can quickly and accurately measure the paint thickness of vehicles. Ideal for car damage inspection, purchase checks, and professional use in the automotive sector. This way, you can easily detect repainted parts and hidden damage.\u003c\/p\u003e\n\u003cp data-start=\"301\" data-end=\"336\" style=\"text-align: center;\"\u003e\u003cstrong\u003eWhy do customers choose AsTools?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"338\" data-end=\"535\" style=\"text-align: center;\"\u003e✓ Quickly and accurately measure paint thickness  \u003cbr data-start=\"380\" data-end=\"383\"\u003e✓ Suitable for various vehicles  \u003cbr data-start=\"424\" data-end=\"427\"\u003e✓ Ideal for purchase and damage inspections  \u003cbr data-start=\"476\" data-end=\"479\"\u003e✓ Fast delivery from stock within Europe  \u003c\/p\u003e\n\u003cp data-start=\"537\" data-end=\"615\" style=\"text-align: center;\"\u003eOrder your paint thickness gauge today and inspect vehicles with confidence!\u003c\/p\u003e","products":[{"product_id":"autool-tg501-lakdiktemeter","title":"Autool TG501 | Paint thickness meter","description":"\u003cdiv style=\"font-family:sans-serif; line-height:1.6; color:#374151; font-size:15px;\"\u003e\n\u003cp\u003e\nThe \u003cstrong\u003eAutool TG501\u003c\/strong\u003e is a \u003cstrong\u003epaint thickness gauge\u003c\/strong\u003e. It measures the thickness of non-conductive coatings on a metal substrate using \u003cstrong\u003etwo measurement principles\u003c\/strong\u003e: magnetic induction for ferromagnetic substrates and the eddy current principle for non-ferromagnetic metals. The measurement range is \u003cstrong\u003e0 to 2000 micrometers\u003c\/strong\u003e, with a resolution of 0.1 micrometers to 100 micrometers and 1 micrometer above that; accuracy is \u003cstrong\u003e3 percent of the measured value plus 1 micrometer\u003c\/strong\u003e.\n\u003c\/p\u003e\n\u003cp\u003e\nIn \u003cstrong\u003eAUTO\u003c\/strong\u003e mode, the instrument automatically selects which of the two principles applies; in \u003cstrong\u003eMAG\u003c\/strong\u003e and \u003cstrong\u003eEDDY\u003c\/strong\u003e mode, you set this manually. Galvanised steel substrates are identified separately, measuring from 3 to 500 micrometres. Measurement requires a \u003cstrong\u003eflat measurement surface with a minimum diameter of 15 millimetres\u003c\/strong\u003e and a substrate of at least 0.30 millimetres steel or 0.05 millimetres non-ferrous metal. Readings are automatically logged during measurement, up to \u003cstrong\u003eeighty records\u003c\/strong\u003e with sequential numbering.\n\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:20px; margin-bottom:40px; align-items:stretch;\"\u003e\n\u003cdiv style=\"flex:1; min-width:250px; background:#ffffff; border:1px solid #e5e7eb; border-radius:8px; padding:25px;\"\u003e\n\u003ch3 style=\"color:#166534; text-transform:uppercase; font-size:13px; font-weight:800; border-bottom:2px solid #22c55e; padding-bottom:12px; margin-top:0;\"\u003eKEY BENEFITS\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eTwo measurement principles in one instrument:\u003c\/strong\u003e Magnetic induction for ferrous and eddy current for non-ferrous, with automatic substrate recognition in AUTO mode.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eResolution 0.1 micrometer to 100 micrometers;\u003c\/strong\u003e accuracy 3 percent of the measured value plus 1 micrometer.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eMemory for eighty readings\u003c\/strong\u003e with sequence number, automatically recorded during measurement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#16a34a; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eZero-point calibration with supplied foils\u003c\/strong\u003e for steel and aluminium, with 1 percent tolerance.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; background:#ffffff; border:1px solid #e5e7eb; border-radius:8px; padding:25px;\"\u003e\n\u003ch3 style=\"color:#991b1b; text-transform:uppercase; font-size:13px; font-weight:800; border-bottom:2px solid #ef4444; padding-bottom:12px; margin-top:0;\"\u003ePOINTS TO NOTE\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eMinimum measurement surface 15 millimetres diameter, flat.\u003c\/strong\u003e Measurement on a welded seam or curved edge is not valid.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eMinimum substrate thickness:\u003c\/strong\u003e 0.30 millimetres for steel, 0.05 millimetres for non-ferrous.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eMeasurement uncertainty 3 percent plus 1 micrometer.\u003c\/strong\u003e Differences of a few micrometers between panels fall within this range and are therefore not significant.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; align-items:flex-start; margin-bottom:12px;\"\u003e\n\u003cspan style=\"color:#dc2626; font-weight:900; margin-right:10px; font-size:16px;\"\u003e✕\u003c\/span\u003e\u003cspan style=\"font-size:14px; color:#4b5563; line-height:1.6;\"\u003e\u003cstrong\u003eMaximum two measurements per second;\u003c\/strong\u003e the instrument switches off after two minutes without operation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eApplication and functionality\u003c\/h2\u003e\n\u003cp\u003e\nFactory paintwork is applied in a controlled process and maintains \u003cstrong\u003econsistent coating thickness\u003c\/strong\u003e across the entire body. Deviations from adjacent panels indicate \u003cstrong\u003erepainting or repair work\u003c\/strong\u003e. The TG501 \u003cstrong\u003equantifies such deviation in micrometres\u003c\/strong\u003e; assessment is based on the \u003cstrong\u003edifference between panels\u003c\/strong\u003e, not an absolute value.\n\u003c\/p\u003e\n\u003cp\u003e\nThe \u003cstrong\u003eAutool TG501\u003c\/strong\u003e supports the following \u003cstrong\u003emeasurement and readout functions\u003c\/strong\u003e:\n\u003c\/p\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFerrous measurement (Fe):\u003c\/strong\u003e Determines coating thickness on steel and other ferromagnetic surfaces using magnetic induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-ferrous measurement (NFe):\u003c\/strong\u003e Measures coating thickness on aluminium, copper, zinc and alloys using the eddy current principle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic mode detection:\u003c\/strong\u003e In AUTO mode it determines whether the surface is ferrous or non-ferrous; in MAG and EDDY you set that choice yourself.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement on galvanised sheet:\u003c\/strong\u003e Detects a galvanised iron substrate separately, from 3 to 500 micrometres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit switching:\u003c\/strong\u003e Toggles the display between micrometres, millimetres and mil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero calibration:\u003c\/strong\u003e Sets the zero point with the supplied calibration foils for steel and aluminium, initiated by holding down the probe mode button.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement storage:\u003c\/strong\u003e Stores up to eighty measurements, each with a sequence number on the display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelete measurement:\u003c\/strong\u003e Deletes the last measurement, or all stored values at once.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"border-left:3px solid #006aff; padding-left:10px; color:#111827; font-weight:800; margin-top:24px;\"\u003eWhat you see on the display\u003c\/h3\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement value:\u003c\/strong\u003e The coating thickness, read to one tenth accuracy up to 100 micrometres and in whole micrometres above that.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected unit:\u003c\/strong\u003e Micrometres, millimetres or mil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe mode:\u003c\/strong\u003e AUTO, MAG or EDDY, and with galvanised sheet a separate indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequence number:\u003c\/strong\u003e The counter for measurements stored in memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"border-left:3px solid #006aff; padding-left:10px; color:#111827; font-weight:800; margin-top:24px;\"\u003eHow to use it\u003c\/h3\u003e\n\u003col style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert the batteries:\u003c\/strong\u003e Three AAA batteries in the compartment on the rear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose the probe mode:\u003c\/strong\u003e AUTO lets the device choose; MAG and EDDY force steel or aluminium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrate the zero point:\u003c\/strong\u003e Hold down the probe mode button; two beeps and the ZO message indicate it has started. On a rough surface, calibrate at multiple points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlace the probe squarely on the panel:\u003c\/strong\u003e The measurement surface must be at least fifteen millimetres in diameter and flat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead and compare:\u003c\/strong\u003e Two measurements per second; work your way across the panels and watch the difference between values, not any single reading.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eSpecial features and capabilities\u003c\/h2\u003e\n\u003cp\u003e\nBeyond the measurement itself, it includes features that make working on a car easier and help \u003cstrong\u003epreserve battery life\u003c\/strong\u003e.\n\u003c\/p\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic screen rotation:\u003c\/strong\u003e The display adjusts to the device's orientation, keeping the measurement value readable when measuring under a door jamb or in a wheel arch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement confirmation:\u003c\/strong\u003e A beep signals that a measurement is complete; during zero calibration initiation, it sounds twice with the ZO indicator displayed on screen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower management:\u003c\/strong\u003e The screen dims after fifteen seconds of inactivity, and the device switches off after two minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration foils in five values:\u003c\/strong\u003e 997, 500, 247, 102 and 50 micrometre, each with a tolerance of 1 per cent, for both steel and aluminium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003eWhere to use it\u003c\/h2\u003e\n\u003cp\u003e\nThe gauge is deployed where the \u003cstrong\u003erepair history of a body\u003c\/strong\u003e is in question and a \u003cstrong\u003emeasured reading\u003c\/strong\u003e carries more weight than a visual assessment.\n\u003c\/p\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-purchase inspection:\u003c\/strong\u003e Compare panel by panel to detect rework not documented on the history report.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValuation and trade-in:\u003c\/strong\u003e Record coating thickness per panel to support value determination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection after damage repair:\u003c\/strong\u003e Confirm that the applied coating matches surrounding panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation for polishing:\u003c\/strong\u003e Determine how much coating thickness is available before material is removed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003ePackage contents\u003c\/h2\u003e\n\u003cul style=\"padding-left:20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Autool TG501 paint thickness gauge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Calibration foil set for steel and aluminium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e Wrist strap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1x\u003c\/strong\u003e User manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#fff7ed; border-left:4px solid #f97316; padding:15px; margin:20px 0; font-size:14px; color:#9a3412; border-radius:0 6px 6px 0; display:flex; align-items:flex-start;\"\u003e\n\u003cspan style=\"font-size:20px; margin-right:12px;\"\u003e💡\u003c\/span\u003e\u003cdiv\u003e\n\u003cstrong\u003eWorth knowing:\u003c\/strong\u003e Measure each panel at \u003cstrong\u003ethree or four points\u003c\/strong\u003e and record the highest and lowest readings. Assessment is based on the \u003cstrong\u003evariation within a panel\u003c\/strong\u003e and on the difference between panels; a single reading contains insufficient information for a meaningful conclusion.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border:0; border-top:1px solid #e5e7eb; margin:40px 0;\"\u003e\n\u003ch2 style=\"border-left:5px solid #006aff; padding-left:15px; font-weight:800;\"\u003e Technical specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; margin:20px 0; border:1px solid #d1d5db;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f9fafb;\"\u003e\n\u003cth style=\"text-align:left; padding:12px 16px; border:1px solid #d1d5db; color:#111827; font-weight:700; width:50%;\"\u003e Specification\u003c\/th\u003e\n\u003cth style=\"text-align:left; padding:12px 16px; border:1px solid #d1d5db; color:#111827; font-weight:700;\"\u003e Description\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003e Brand\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eAutool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eTG501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003e Type\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003ePaint thickness gauge, ferrous and non-ferrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eMagnetic induction for steel, eddy current for non-ferrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eProbe types\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eAUTO, MAG and EDDY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e0 to 2000 micrometres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eGalvanised substrate\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e3 to 500 micrometres, separately identified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e0.1 micrometre to 100 micrometres; above that 1 micrometre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e3 percent of the measured value plus 1 micrometre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMeasurement speed\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eMaximum two measurements per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMinimum measurement area\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e15 mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMinimum substrate thickness\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e0.30 mm steel, 0.05 mm non-ferrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eUnits\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eMicrometre, millimetre and mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eUp to eighty measurements, with sequential numbering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eZero-point calibration using the supplied foils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eBacklit LCD with automatic screen rotation; dims after fifteen seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eAuto shut-off\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eAfter two minutes without operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eThree 1.5 V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eABS, protection rating IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e−10 °C to +50 °C, 20 to 90 percent relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003e130 × 58 × 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; font-weight:700; color:#111827;\"\u003eArticle number\u003c\/td\u003e\n\u003ctd style=\"padding:12px 16px; border:1px solid #d1d5db; color:#111827;\"\u003eTG501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Autool","offers":[{"title":"Default Title","offer_id":53396921647411,"sku":"TG501","price":77.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0912\/5874\/9235\/files\/Autool-TG501-Lakdiktemeter.webp?v=1780309989"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0912\/5874\/9235\/collections\/224e26d9-abe0-2b6a-7c6f-a28049c63526.jpg?v=1779962308","url":"https:\/\/www.astools.eu\/collections\/paint-thickness-gauge.oembed","provider":"AsTools","version":"1.0","type":"link"}